Mr. Bickel,

To follow up on our call today, we would like to make a correction of the transmitter output power on the license to cover
recently granted for new FM station WYBO(FM), Waynesboro GA (FID#166071, BLH-20160322ADT), issued 3/29/16. In
preparing the license to cover application, the permittee took the transmitter output power of 4.679 kw (rounded up to 4.7
kw on the granted license) from a "System Data Sheet' in a February email from the antenna manufacturer representative
that was incorrect (for one, it was based on a previously authorized ERP of 6 kw, before the construction permit was
modified for a higher height on the tower with a corresponding reduction in ERP); a copy of that incorrect System Data
Sheet is attached.
On the day the license was granted, a copy of the license was circulated to the licensee by email, with a copy to the
consulting engineer (who was not involved in the actual construction of the station or preparation of the license to cover
application, for which the permittee relied on a local engineer), and the consulting engineer immediately noticed and
advised that the transmitter output power appeared incorrect. The licensee promptly chocked with the antenna
manufacturer and was advised of the correct transmitter output power to achieve the authorized ERP of 4.3 kw, which is a
transmitter output power of 2.123 kw (a copy of the revised, corrected System Data Sheet showing the calculation of the
correct 2.123 transmitter output power is also attached for your reference); as a result, I understand that when the station
operated after the license and program test authority was granted, it has been at this lower, correct transmitter output
power, to achieve the correct, authorized ERP.
If as we discussed the license may be just re-issued with the correct transmitter output power of 2.123 kw, that would be
appreciated, but if you need any additional information or filings in order to get this corrected, please let me know. Thank
you for your assistance!
Jeff Tim mons
ieff(timmonspc.com
Jeffrey L. Timmons, Esq.
974 Branford Lane NW
Lilburn, Georgia 30047-2680
Office/Cell: (678) 463-5116
FacsimiLe: (678) 487-8936

Virus-free. www,avas

rn

		

(814)472-5436

(800) 762-7743

Fax: (814) 472-5552

SYSTEMS WITH RELIABILITY, LP
Broadcast Antenna & Transmission Systems

Customer
Contact
Location
Antenna Model
Channel I Frequency

NEW
Dan Sessler
Waynesboro, GA
FM3/2-0.7SWS-DA
92.9
MHz

Polarization Type
Polarization Ratio

Circular

H-PoI. (PRH)
V-PoI, (PRV)
Elevation Directivity (ED)
Azimuth Directivity (AD) H-PoI.
Azimuth Directivity (AD) V-PoI.

50.000
50.000
1.870
1.595
1.595

Antenna Efficiency

100.000

%

Antenna Gain (GH)
H-PoI. (GH)
V-Pol. (GV}

1.491
1.491

H-Pol (AGH)
V-PoI (AGV)

1.735
1.735

H-PoI. (ERPH)
V-Pol. (ERPV)

8.000
6.000

dB Gain (AG)

ERP

Line Type
Attenuation per 100 ft.
Line Length (LL) AGL + 25'
Total Line Attenuation
Line Efficiency (LE)
Line Loss (LPL)
Antenna Input Power (AlP)
Reqd. Transmitter Output Power

kW
kW

1 5/8 Foam LCF158-5OJA
dBIlOOft
0.190
34410
ft.
0.65
dB
86.00
%
0.65
kW
4.02
kW
4.679
kW

MECHANICAL SPECIFICATION
No. Of Bays
Antenna Aperture
Antenna Total Length
Center of Radiation AGL
Antann Woight (W/O Brackets, Directors)
Windload (51)133)1 CaAc

2
7.94
16.94
39.70
99.50
525.00

ft.
ft.
ft.
lbs.
lbs. 50/33PSF

2.42
5.16
97.44
45.23
15.00

m
m
m
kg
ftA2

Mechanical Specifications will be certified upon final construction and testing.
Note: Given values can be used for planning system.

Prepared by:
Kevin W. Rager
SWR, LP Engineering

2/1712016

	

Exhibit 5: Antenna Data Sheet

SYSTEMS WITH RELIABILITY, LP
BROADCAST ANTENNAS AND TRANSMiSSION LINE

SYSTEM DATA. SHEET
Customer
Contact
Location
Antenna Model
Channel I Frequency

WYBO
Dan Sessler
Waynesboro, GA
FM3/2-C .75WS-DA
92.9 MHz

ELECTRICAL SPECIFICATIONS
Antenna Specifications:
dB

H-POL
License ERP ( KW)

4.300

FCC Limit Pattern Directivity
Elevation Directivity
Azimuth Directivity
Composite Pattern
Polarization Ratio
RMS Comp./RMS Limit
Antenna Efficiency %
Power Ratio ( P01. Ratio X Efficiency)
Antenna Gain

1 595
1.870
3.297
1.839
0.384

V. Pol.

dB

4.300
2.027
2.718
5.182
2.645

dB
dB
dB
dB

1.595
1.870
2.053
1.839
0.616

2.027 dB
2.718 dB
3.124 dB
2.645 dB

93.1 %
100
0.3837
2.366

Antenna Input Power (1(W)

3.740

1.817kW

dB

100
0.6163
2.366

3.740

dB

2.595 (dBK)

Feed Line Specifications:
Line Type: Andrew
Attenuation Per 100 ft (dB)
Line Length (It) AGL + 50 Horizontal Run
Total Line Attenuation (dB)
Line Efficiency
Power Input to the Line (KW)

1

Air 50 fl HCAI58-50J
0.19 dB
355.00 ft.
0.6745 dB
85.62 %
2.123 kW
3.269 (dBK)

5/8

I ['? I [..J l1
No.Qf Bays
Antenna Aperture
Center of Radiation AGL
Antenna Weight (Everything)
Windload (50133) wl Mount. Pipe

2
7.94 ft.
330.00 ft.
506.00 lbs.
525.00 lbs.

Windload CaAc

2.42
100.58
230.00
15.00

meter
meter
kg
ftA2

Kevin W. Rager